The Ohio State University
 
 
   
The Ohio State University College of Medicine & Public Health
Leica TCS SL

 
Home > Services/Core Grant > Imaging Core > Leica TCS SL

Services/Core Grant

Confocal

The Leica TCS SL is the Imaging Core's confocal system and has these unique features.  Click here for a detailed description.Leica Confocal Microscope

  • In place of excitation filters, our confocal system has an acousto-optical tunable filter which allows:
    • Allows for independently attenuating each laser line
    • Less Crosstalk with multi-color stainings
    • Less bleaching by optimized excitation intensity
    • Fast switching - While the laser is scanning, it can be turned on in one spot and in the next spot it can be turned off
    • Region-of-interest Scan
      • Sample protection
      • Bleaching experiments (FRAP, FRET)
      • Activation/uncaging

  • In place of emission filters, our confocal system has spectral detectors
    • No limitations caused by filter characteristics
    • Stepless adjustable spectral emission bands
    • Adjust detection bandwidth manually or with pre-sets

Microscope

The microscope used with this system is the Leica DM IRE2.  It is completely electronic and equipped with the following objectives and filter cubes.

OBJECTIVES

Name

Numerical Aperture

Resolution at 520nm (mm)

Working Distance

Coverslip thickness

Immersion Medium

Condenser Phase
Annulus

Objective DIC Prism

Condenser DIC Prism

Correction Collar

100x HCX Plan Apo CS oil

0.70-1.40

0.45-0.23

90 mm

0.17mm

oil

 

D

63/100

Numerical Aperture

63x HCX Plan Apo CS oil

0.6-1.40

0.52-0.23

100mm

0.17mm

oil

 

E

63/100

Numerical Aperture

40x HCX Plan Apo CS oil

0.75-1.25

0.42-0.25

100mm

0.17mm

oil

 

E

40/63

Numerical Aperture

20x HC Plan Apo CS multi-imm

0.70

0.45

260mm

 

oil/ glycerol/
water

 

C

20

Immersion Medium

 

 

 

 

 

 

 

 

 

 

40x HCX Plan Fluotar Ph2

0.75

0.24

400mm

0.17mm

dry

Ph2

 

 

none

10x HC Plan Fluotar Ph1

0.30

1.06

11mm

 

dry

Ph1

 

 

none

FILTER CUBES

STANDARD

Label

Technical name

Excitation

Dichroic

Emission

Fluorochrome Examples

GRN

I3

BP 450-490

510

LP 515

Alexa 488, Cy2, YFP

RED

N2.1

BP 515-560

580

LP 590

Alexa 546, TRITC, Cy3

FAR

Cy5

BP 590-650

660

BP 663-738

Alexa 647, Cy5, TOTO-3

OTHER

CFP

Cyan GFP

BP 426-446

455

BP 460-500

CFP

 

 



© 2008 Center for Molecular Neurobiology
206 Rightmire Hall
1060 Carmack Road
Columbus, OH 43210
The Ohio State University